High-capacity gearless performance for demanding elevator applications
The Imperial Electric 908-OB is a gearless AC traction machine designed for elevator systems requiring exceptional capacity, high operating speeds, and dependable double-wrap traction performance.
Combining permanent magnet motor technology with a robust machine design, the 908-OB is suited to both modernization projects and new installations. With capacities up to 16,000 lbs and speeds up to 2,000 FPM, it is designed for demanding passenger and service elevator applications in high-rise and high-traffic buildings.
Built for demanding elevator applications
The 908-OB is engineered for projects where elevator performance, capacity, and reliability are critical.
Designed to support high-capacity passenger and service elevators, the machine combines substantial load-handling capability with the traction performance required for demanding installations. Its double-wrap design helps maintain dependable operation in applications where conventional traction arrangements may not be sufficient.
Performance for everyday operation
The 908-OB combines permanent magnet motor technology with precise speed control to support smooth elevator operation.
With speeds reaching 2,000 FPM and capacities up to 16,000 lbs, the machine is suitable for high-rise buildings and busy transportation environments. Precise low-speed control supports accurate leveling, smooth acceleration and deceleration, and consistent ride quality throughout daily operation.
Engineered for dependable operation
The 908-OB incorporates a four-calliper brake arrangement consisting of two primary brake calipers and two emergency brake calipers.
Dual independent brakes are designed to hold 125% of rated capacity, helping support dependable stopping performance without the need for an external rope brake. Combined with heavy-duty construction and substantial shaft load capability, the machine is designed to support reliable long-term operation.
Where does the 908-OB fit?
Ideal for:
- High-rise buildings
- Commercial office towers
- Healthcare facilities
- Hotels
- Mixed-use developments
- High-capacity passenger elevators
- Service elevators
- New construction projects
- Elevator modernization projects
- Overhead installations
- Basement installations
- Side-pull applications
Why choose the 908-OB?
The 908-OB combines high-capacity load handling, high-speed performance, and advanced gearless AC technology within a single traction machine platform.
With capacities up to 16,000 lbs, speeds up to 2,000 FPM, and a heavy-duty braking system designed for demanding applications, it provides a practical solution for elevator projects where performance, reliability, and operational confidence are essential.
FAQ
What capacity can the 908-OB support?
The 908-OB supports elevator applications with capacities up to 16,000 lbs in a 2:1 roping configuration.
What speeds can the 908-OB achieve?
The machine supports speeds up to 2,000 FPM in 1:1 roped applications.
What traction configuration does the 908-OB use?
The 908-OB is designed for double-wrap traction applications and supports both 1:1 and 2:1 roping configurations.
What braking system is used on the 908-OB?
The machine incorporates dual independent brakes and a four-caliper braking arrangement consisting of two primary brake calipers and two emergency brake calipers.
Does the 908-OB require an external rope brake?
The braking system is designed to hold 125% of rated capacity, eliminating the need for an external rope brake in supported applications.
What installation configurations are available?
The 908-OB can be applied in overhead, basement, and side-pull installations.
Can the 908-OB be used for modernization projects?
Yes. The machine is suitable for both modernization projects and new elevator installations.
What are the benefits of permanent magnet technology?
Permanent magnet motor technology supports efficient gearless operation, precise speed control, and smooth elevator performance across a wide range of operating conditions.
How do I determine whether the 908-OB is right for my project?
-
MODEL 908 OB-E- 4,500 lbs capacity Up to 1,400 fpm 1:1 Roping
- 9,000 lbs capacity Up to 700 fpm 2:1 Roping
- Double wrap
- 30.0” drive sheave
- Rope Groove hardness: 245-285 Brinell
- Up to Qty 9-5/8 or 7-3/4” ropes Double Wrap
- Round U Groove
- D:d ratio 48:1 with 5/8” ropes
- D:d ratio 40:1 with 3/4” ropes
- Sheave shaft Load: 120,000 lbs
- Quad Independent disk brake system holds 125% rated capacity-2 each
- Overhead, Basement & Side pull Application
- Extra mounting restraints are needed for Basement & Side pull Application
- M/C Weight: 14,200 lbs
- M/C Torque:
- Rated Torque 908 OB 4853 ft-lb, Accel Torque: 12132 ft-lb
-
Model 908 OB-H- 8,000 lbs capacity Up to 2,000 fpm 1:1 Roping
- 10,000 lbs capacity Up to 1,000 fpm 1:1 Roping (Special Applications)
- 16,000 lbs capacity Up to 1,000 fpm 2:1 Roping
- Double wrap
- 30.0” drive sheave
- Rope Groove hardness: 245-285 Brinell
- Up to Qty 9-5/8 or 7-3/4” ropes Double Wrap
- Round U Groove
- D:d ratio 48:1 with 5/8” ropes
- D:d ratio 40:1 with 3/4” ropes
- Sheave shaft Load: 120,000 lbs
- Two Independent Hydraulic disk brake system holds 125% rated capacity - 2 each
- Overhead, Basement & Side pull Application
- Extra mounting restraints are needed for Basement & Side pull Application
- M/C Weight: 15,200 lbs
- M/C Torque:
- Rated Torque 908 OB – 6490 ft-lb, Accel Torque: 16225 ft-lb
Capacity up to 16,000 lbs (2:1 roping)
Speeds up to 2,000 FPM (1:1 roping)
Maximum sheave shaft load of 120,000 lbs
Maximum suspended load of 60,000 lbs
Double-wrap traction design
AC permanent magnet motor technology
Dual independent brake system
Four-caliper braking arrangement
125% rated load holding capability
Supports both 1:1 and 2:1 roping configurations
Suitable for overhead, basement, and side-pull applications
Oil-free gearless design
Brochures
Press Releases
News Articles
Case Studies
Survey Form - PDF
Survey Form - Word
Quote Form - PDF
Quote Form - Word
Product Catalogs
Product Data Sheets
Training
Manuals
Product Page
Quote Form
Survey Form
Notice
Frame 908-OB E Series 1:1 Duty Table
| FPM | 500 | 700 | 800 |
1000 |
1200 | 1400 | 1600 | 1800 | 2000 | |||||||||
| Freq. (Hz) | 17 | 23.8 | 27.2 | 34 | 40.7 | 47.5 | 542.3 | 61.1 | 67.9 | |||||||||
| RPM | 63.7 | 89.1 | 102 | 127.3 | 152.8 | 178.3 | 203.7 | 229.2 | 254.6 | |||||||||
| Capacity | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
| 2000 | 16.8 | 37 | 23.6 | 37 | 26.9 | 37 | 33.7 | 44 | 40.4 | 53 | 47.1 | 64 | 53.9 | 67 | 60.6 | 83 | 67.3 | 83 |
| 2500 | 21 | 46 | 29.5 | 46 | 33.7 | 46 | 42.1 | 55 | 50.5 | 66 | 58.9 | 80 | 67.3 | 84 | 75.8 | 104 | 84.2 | 104 |
| 3000 | 25.3 | 56 | 35.4 | 56 | 40.4 | 56 | 50.5 | 67 | 60.6 | 79 | 70.7 | 97 | 80.8 | 101 | 90.9 | 124 | 101.0 | 124 |
| 3500 | 29.5 | 65 | 41.2 | 65 | 47.1 | 65 | 58.9 | 78 | 70.7 | 93 | 82.5 | 113 | 94.3 | 118 | 106.1 | 145 | 117.8 | 145 |
| 4000 | 33.7 | 74 | 47.1 | 74 | 53.9 | 74 | 67.3 | 89 | 80.8 | 106 | 94.3 | 129 | 107.7 | 134 | 121.2 | 166 | 134.7 | 166 |
| 4500 | 37.9 | 84 | 53 | 84 | 60.6 | 84 | 75.8 | 100 | 90.9 | 119 | 106.1 | 145 | 121.2 | 151 | 136.4 | 187 | 151.5 | 187 |
| Model 908-OB E | All specifications at 50% Counterweight. Consult Imperial Electric for 40% and 45% counterweighting data. |
|||||||||||||||||
Frame 908-OB H Series 1:1 Duty Table
| FPM | 500 | 700 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | |||||||||
| Freq. (Hz) | 17 | 23.8 | 27.2 | 34 | 40.7 | 47.5 | 542.3 | 61.1 | 67.9 | |||||||||
| RPM | 63.7 | 89.1 | 102 | 127.3 | 152.8 | 178.3 | 203.7 | 229.2 | 254.6 | |||||||||
| Cap. | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
| 5000 | 42.1 | 93 | 58.9 | 93 | 67.3 | 93 | 84.2 | 111 | 101.0 | 132 | 117.8 | 161 | 134.7 | 168 | 151.5 | 207 | 168.4 | 207 |
| 5500 | 46.3 | 102 | 64.8 | 102 | 74.1 | 102 | 92.6 | 122 | 111.1 | 146 | 129.6 | 177 | 48.1 | 185 | 166.7 | 228 | 185.2 | 228 |
| 6000 | 50.5 | 112 | 70.7 | 112 | 80.8 | 112 | 101.0 | 133 | 121.2 | 159 | 141.4 | 193 | 161.6 | 202 | 181.8 | 249 | 202.0 | 249 |
| 6500 | 54.7 | 121 | 76.6 | 121 | 87.5 | 121 | 109.4 | 144 | 131.3 | 172 | 153.2 | 209 | 175.1 | 218 | 197.0 | 270 | 219.9 | 270 |
| 7000 | 58.9 | 130 | 82.5 | 130 | 94.3 | 130 | 117.8 | 155 | 141.4 | 185 | 165.0 | 225 | 188.6 | 235 | 212.1 | 290 | 235.7 | 290 |
| 7500 | 63.1 | 139 | 88.4 | 139 | 101.0 | 139 | 126.3 | 166 | 151.5 | 198 | 176.8 | 241 | 202.0 | 252 | 227.3 | 311 | 252.5 | 311 |
| 8000 | 67.3 | 149 | 94.3 | 149 | 107.7 | 149 | 134.7 | 177 | 161.6 | 212 | 188.6 | 257 | 215.5 | 269 | 242.4 | 332 | 269.4 | 332 |
| Model 908-OB H | All specifications at 50% Counterweight. Consult Imperial Electric for 40% and 45% counterweighting data. |
|||||||||||||||||
Frame 908-OB E Series 2:1 Duty Table
| FPM | 350 | 400 | 450 |
500 |
700 | 800 | 1000 | |||||||
| Freq. (Hz) | 23.8 | 27.2 | 30.6 | 34 | 47.5 | 54.3 | 67.9 | |||||||
| RPM | 89.1 | 102 | 114.6 | 127.3 | 178.3 | 203.7 | 254.6 | |||||||
| Capacity | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
| 3000 | 18.7 | 30 | 21.4 | 30 | 24.1 | 35 | 26.7 | 35 | 37.4 | 51 | 52.8 | 53 | 53.5 | 66 |
| 4000 | 25.0 | 39 | 28.5 | 39 | 32.1 | 47 | 35.7 | 47 | 49.9 | 68 | 57.0 | 71 | 71.3 | 88 |
| 5000 | 31.2 | 49 | 35.7 | 49 | 40.1 | 59 | 44.6 | 59 | 62.4 | 84 | 71.3 | 89 | 89.1 | 110 |
| 6000 | 37.4 | 59 | 42.8 | 59 | 48.1 | 70 | 53.5 | 70 | 74.9 | 102 | 85.6 | 107 | 107.0 | 132 |
| 7000 | 43.7 | 69 | 49.9 | 69 | 56.1 | 82 | 62.4 | 82 | 873 | 119 | 99.8 | 125 | 124.8 | 154 |
| 8000 | 49.9 | 79 | 57 | 79 | 64.2 | 94 | 71.3 | 94 | 99.8 | 136 | 114.1 | 142 | 142.6 | 176 |
| 9000 | 56.1 | 89 | 64.2 | 89 | 72.2 | 106 | 80.2 | 106 | 112.3 | 153 | 128.3 | 160 | 160.4 | 198 |
| Model 908-OB E | All specifications at 50% Counterweight. Consult Imperial Electric for40% and 45% counterweighting data. |
|||||||||||||
Frame 908-OB H Series 2:1 Duty Table
| FPM | 350 | 400 | 450 |
500 |
700 | 800 | 1000 | |||||||
| Freq. (Hz) | 23.8 | 27.2 | 30.6 | 34 | 47.5 | 54.3 | 67.9 | |||||||
| RPM | 89.1 | 102 | 114.6 | 127.3 | 178.3 | 203.7 | 254.6 | |||||||
| Capacity | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps | HP | Amps |
| 10000 | 62.4 | 98 | 71.3 | 98 | 80.2 | 117 | 89.1 | 117 | 124.8 | 170 | 142.6 | 178 | 178.3 | 220 |
| 11000 | 68.6 | 108 | 74.4 | 108 | 88.2 | 129 | 98.0 | 129 | 137.3 | 187 | 156.9 | 196 | 196.1 | 242 |
| 12000 | 74.9 | 118 | 85.6 | 118 | 96.3 | 141 | 107.0 | 141 | 149.7 | 204 | 171.1 | 214 | 219.9 | 264 |
| 14000 | 87.3 | 138 | 99.8 | 138 | 112.3 | 164 | 124.8 | 164 | 174.7 | 239 | 119.6 | 249 | 249.6 | 307 |
| 15000 | 93.6 | 148 | 107.0 | 148 | 120.3 | 176 | 113.7 | 176 | 187.2 | 256 | 213.9 | 267 | 267.4 | 329 |
| 16000 | 99.8 | 158 | 114.1 | 158 | 128.3 | 188 | 142.6 | 188 | 199.6 | 273 | 228.2 | 285 | 285.2 | 351 |